Model |
Spectral Response mm |
Tmin °C |
Tmax °C |
Application/Material |
LS15.01 |
2.00…2.70 |
300 |
2400 |
metals, metal oxides, ceramics, glass volume |
LS15.21 |
3.43 ± 0.15 |
80 |
350 |
plastic film with CH-band, coating materials (oil,paints) |
LS15.23 |
6.80 ± 0.15 |
0 |
400 |
thin film plastics, e.g. PE, PP, PVC |
LS15.24 |
7.93 ± 0.15 |
0 |
400 |
thin film plastics, e.g. PET, PA, fluor carbon |
LS15.25 |
8.05 ± 0.15 |
0 |
400 |
thin film plastics, e.g. PTFE, PET, PVC |
LS15.41 |
3.90 ± 0.10 |
250 |
2500 |
glass volume, measurements through hot gases and flames |
LS15.42 |
4.90…5.50 |
100 |
2500 |
glass (processing), quartz |
LS15.43 |
7.50…8.20 |
0 |
2500 |
glass (thin plates), quartz, ceramics |
LS15.69 |
x…y |
400 |
2500 |
hot gases in incinerators and fossil fuel fired utility boilers, rotary kiln |
LS15.82 |
8…14 |
-50 |
1000 |
paper, textiles, rubber, wood, ceramics, thicker plastics (>1mm), painted or coated surfaces, asphalt, building materials, electronic components, food, liquids |
LS15.85 |
9.6…11.5 |
-25 |
200 |
meteorological, biological, agricultural studies |
LS15.99 |
other spectral and temperature ranges are available |
General Specifications:
Temperature Range |
Depends on model, minimum and maximum measuring temperature; see table above |
Temperature resolution (NETD)* |
Depends on model, measuring temperature and response time; typical value ± 0.2° C |
Accuracy |
± 0.9° C ± 0.9% of the difference between target temperature and housing temperature |
Long-term stability |
Better than 0.01% of the absolute measured temperature in Kelvin/month |
Scanning angle |
90° maximum scanning angle is freely programmable |
Angle resolution |
0.057° |
Scanning speed |
Up to 90° /s |
Measuring points |
< 0.014° step, 1-900°/sec, up to 1001 points |
Aiming options* |
Several optical and mechanical options are available, e.g. laser pointer |
Emissivity setting |
Adjustable from 0.1 to 1.0 programmable in 0.001 increments. Individual programmable for every measuring point |
Analog output |
4 scalable output signals; linear voltage or current 0…1 V or 0…10 V or 0…20 mA or 4…20 mA (programmable) |
Serial interface |
RS-232 interface, bi-directional, baud rate up 230 kbps
RS-485 up to 921 kbps |
Power requirements |
22…30 VDC or 24 VAC ± 10%, 48...400 Hz; #250 mA with 24 VDC |
Permissible ambient temperature |
-20° to +70°C |
Storage temperature |
-20°C...70°C |
Air purge |
Airflow rate 3…5 m3 /h at 0.3...0.5 bar (industrial air) |
Housing protection, weight |
IP 65 (DIN 4005) NEMA 4 equivalent, approx. 2 kg |
* Please ask for further data on Infrared Radiation Pyrometer KT15 Series (temperature ranges, temperature resolution, field of view): "Technical Data", "Field of View Diagrams", "Options and Accessories".